One school, a day of air.

The same inspection in every building. A robot scans, a PE signs, fixed sensors watch between visits, and it all lands in one record the facilities team and the compliance officer can both use.

Fairfax County Public Schools SB 1413 / HB 2618 ● live from field capture + sensors illustrative sample data
Schools
250
Inspected
248
Compliance
97%
Open deficiencies
412
Monitored zones
1,840
Every hour

CO2 in one classroom

CO2 tells you if a room is ventilated. It climbs as the room fills, drops when fresh air keeps up. Here it goes over the line by mid-morning and stays there.

CO2 (ppm) Occupied hours 1,100 ppm ventilation threshold
Room 109 · Fairwood Elementary · sample day. Peak 1,300 ppm at 09:00.
The twin

The school in 3D

Each room shows its live CO2 and ventilation status, with sensors and units where they physically sit. You see where a problem is, down to the room.

Good < 1,000 Watch 1,000–1,200 Exceeds > 1,200
Room109 · Classroom
CO21,360 ppm
VentilationFail
Served byAHU-2 · MERV-13
Outside air41% of design
EvaluatorPE signed · A. Patel
⚠ Open deficiency · P1
AHU-2 outdoor-air damper stuck closed. OA flow 41% of ASHRAE 62.1 design. Recommend actuator replacement.
The moves

What we check

Seven checks, one standard, recorded once. Robots do the capture. A licensed PE makes the call and signs it.

01

Verifies the filter

Installed MERV rating and condition confirmed at every air handler, against a MERV-13 target and documented per unit.

Filter efficiency
02

Measures the outside air

Direct measurement first. Outside-air flow read at the unit and checked against design ventilation rates, not assumed.

Outside air · airflow · static pressure
03

Reads the room

CO2 sampled in occupied zones, spot at inspection or logged continuously by a fixed sensor between cycles.

CO2 monitoring
04

Signs to the standard

Compliance with ASHRAE 62.1 and Virginia requirements, evaluated and signed by a mechanical engineer, one of the statute's named evaluators.

ASHRAE 62.1 · PE of record
05

Watches between cycles

In-production fixed sensors stream CO2, PM, and VOC into the platform, so a failing unit is caught in days, not at the next inspection.

Continuous monitoring
06

Rolls to the portfolio

Every finding becomes a prioritized, costed line in a district dashboard, exportable to GIS and the CMMS, and a defensible compliance record.

Deliverables · capital planning
The record

All schools at a glance

One row per school, colored by what matters. Each status comes straight from the readings under it.

SchoolTypeLast insp.Avg CO2FiltrationVentilationDef.Status
Fairwood ElementaryElem2026-03-12842 ppmMERV-13Pass3Pass
Meadowbrook ElementaryElem2026-03-11690 ppmMERV-13Pass2Pass
Lakeside HighHigh2026-02-27760 ppmMERV-13Pass5Pass
Cardinal MiddleMiddle2026-03-091,180 ppmMERV-11Watch9Watch
Fairfax High AnnexHigh2026-03-04980 ppmMERV-11Watch7Watch
Ridgecrest ElementaryElem2026-03-151,410 ppmMERV-8Fail14Fail